Series EHM Electronic Hour Meter

Series EHM Electronic Hour Meter


 

Quick Specs...

  • Attractive 5mm 6-digit LCD display
  • High reliability non-volatile memory
  • Wide voltage range
  • Wide industrial temperature range
  • Snap-fit panel mounting
  • Hourglass operation indicator
  • Low power consumption
  • Reverse polarity protection (85VDC)


Buy Online

Printer-friendly Version

Dimensional Diagrams

 

Overview Industry/Application Specifications Related Info

Overview / Design Principle:

The Veeder-Root brand Series EHM hourmeter provides an industrial environment time monitoring function.

There are three versions of the hourmeter with identical functionality:

  • Round Meter – 2.4" panel bezel
  • Rectangular Meter – 2.09" x 1.23" panel bezel
  • PCB Mount Meter

All are entirely fashioned from high strength plastic and feature a highcontrast LCD display.

Features and Benefits:

  • Attractive 5mm 6-digit LCD display
  • High reliability non-volatile memory
  • Wide voltage range
  • Wide industrial temperature range
  • Snap-fit panel mounting
  • Hourglass operation indicator
  • Low power consumption
  • Reverse polarity protection (85VDC)

Ideal For:

Recording and displaying an elapsed time but performs no output function. Various models available with LED or LCD displays.

Key Application / Industry:

  • Running Hours, Motor RPM
  • Industries: Construction Equipment; Lawn & Garden, Generator, Recreational (Golf)
Standard Features
Accuracy: ±2 sec over temperature
Display: 6-digit LCD, 5 mm high
Power: 9-85VDC @ 4mA max.
Non-Volatile Memory: Exclusive Error Detection/Error Correction algorithm
provides single fault error of less than 4 seconds over 100,000 hours.
Range & Resolution: 99999.9 hours @ 0.1 hour resolution
Timing Activation: 9-85VDC
Timing Indication: Hourglass Icon
Termination: Blade terminals; 1/4" on round case; 3/16" on rectangular case
EMC Susceptibility: EN61000-4-2 for industrial environments
EN50082-1 for commercial and light industrial environments.
EMC Emissions: EN50081-1 for light industrial environments
EN50081-2 for industrial environments
Operating Temperature: -40°C to +85°C (LCD response degrades < -30°C and > +75°C)
Storage Temperature: -40°C to +85°C (LCD glass freezes at -40°C)
Humidity: 5% to 95% RH non-condensing
Safety: Low Voltage Directive Safety Requirements EN61010-1
Vibration: SAE J 1378 20g
Mechanical Shock: SAE J 1378 55g
Environmental Sealing: NEMA4X